BE1 Numerical Protection Systems 

BE1 Numerical Protection Systems


BE1 Numerical Protection Systems are available in rack mount or retrofit friendly packages for any application. Visit the Logic Library for common application examples and BESTlogicPlus programmable logic files.

Divider Line


BE1-11
g Generator Protection System 

Product Bulletin

Instruction Manual

Protocol Manuals

Product Software

Application Guides

Guideform Specifications and Drawings

Bulletin URJ(includes stylechart)

BE1-11g Manual

DNP3 Manual

BESTCOMSPlus

Generator Protection

MicrosoftWorddoc  BE1-11g Specs

 

 

Modbus Manual

BEST61850

Transformer Protection

AdobeReaderlogo BE1-11g Specs

 

 

IEC 61850 Manual

 

 

Product Drawings

Click here for Application Notes and other Resources

 

BE1-11g Generator Protection System

Available in
fully drawout
half rack case

The BE1-11g is a multifunction numerical protection system that provides the comprehensive suite of functions for the protection of generators from faults and abnormal operating conditions. The BE1-11g provides three phase, ground, and negative sequence directional or non-directional overcurrent protection, forward or reverse power protection, VAR and impedance based loss of field, breaker failure, over/underfrequency, over/undervoltage and sync check, breaker monitoring and control, sequence-of-events recording, fault reporting, rate-of-change frequency, and metering functions, all in an integrated system.

 
Protective Relays
Application Table
Application Engineers
Regional Sales Managers
Sales Reps
Previous page Next Page


Device Functions
 

24 - Volts per Hertz 25 - Sync-Check 27 - Undervoltage
       
  32 - Directional Power 40 - Field Relay 43 - Manual Transfer
       
  46 - Reverse Phase Sequence 47 - Phase Sequence 50 - Instantaneous Overcurrent
       
  51 - AC Time Overcurrent 59 - Overvoltage 60 - Voltage Balance
       
  62 - Time Delay 67 - AC Directional Overcurrent 81 - Frequency Relay
       
  101 - Virtual breaker control BF - Breaker Failure  
           
  Ethernet Option
           
Modbus Option

  DNP3 Option
BESTCOMSPlus Makes it Easy
 
See How to Verify Your Settings the EASY way


Standard features include:

  • Each overcurrent element can be individually set for forward or reverse directional or non-directional control for maximum flexibility in any application.
  • Includes distance to the fault to aid in timely fault location and service restoration.
  • BESTlogicPlus provides the user with complete flexibility in configuring a protection and control system. User programmable variable and switch names make these relays completely self documenting.
  • Large high-contrast programmable 128x64 LCD display allows the relay to replace local indication and control functions, such as metering, alarm annunciation, and control switches.
  • Four "Table Lookup" time curves create custom curve shapes using 2-40 points
  • Three independent communication ports with protocol support allows integration with distributed control systems.
  • Optional RS-485 and copper or fiber Ethernet communications, Modbus™ , and DNP3 protocols
  • Available with optional IEC 61850 implementation
  • Web page and user-selectable email triggers for remote alarm reporting
  • High-speed BESTCOMSPlus™ user interface via USB
  • Power Quality reporting
  • Non-volatile expanded event memory
  • Includes Real Time Clock with 8 hour capacitor ride through and battery backup. 

Application Notes and Technical Papers and other Resources

Application Notes
- Application Note PC-COM01- Basic instructions for setting up HyperTerminal and Terminal
-
Application Note PC-59N01 - A discussion of two methods to determine the zero sequence component of the line voltage and tripping with the 59N function
-
Mathcad file for PC-59N01
- Application Note PC_RTF Compare - Instructions for an easy way to quickly and accurately compare two numeric relay settings files using BESTCOMS and Microsoft® Word.
-
Application Note PC-2502 - Understanding and applying the sync check (25) phase angle compensation in Basler numeric relays.
-
Application Note PC-GPS01 - Generator Reverse Power Protection (32) Replacement Opportunities (GE Type GGP-53C and ABB Type CW) offer additional protection from Loss of Prime Mover
-
Application Note PC-ArcFlash - Arc Flash Hazard Mitigation Through Relaying

Technical Papers
-
Protective Relaying Methods for Reducing Arc Flash Energy
- A Review of Negative Sequence Current
- Load Shedding for Utility and Industrial Power System Reliability
- Voltage Restrained Time Overcurrent Relay Principles, Coordination, and Dynamic Testing Considerations
  MathCad simulation for Voltage Restrained paper
- Reliability Considerations of Multifunction Protection
- Myths of Protecting the Distributed Resource To Electric Power System Interconnection
- Distributive Generation and Interconnection: Protection, Monitoring, and Interconnection Opportunities
- Breaker Monitoring with Numerical Relay
- Commissioning Numerical Relays

Other Resources
- BNS Time Current Characteristic Spreadsheet

ISO Certificate Link