Visit the Basler web site Basler Electric Basler Electric Jobs at Basler Site Map
Link to Home Link to Company Info Link to Products Link to Newsletter Information/Support Help
Protection and Control Systems Spacer Regulation and Systems Control Spacer Static Excitation Systems Spacer Magnetic Product Group Spacer Order Online Link


Choose the purpose of your protection scheme:
  - Clear Faults
  - Relieve Stress
  - Restore Power
  - Preserve System

Choose the relay type and the zone you would like to protect on the chart below.
 

Protective Relays
Application Table
Application Engineers
Regional Sales Managers
Sales Reps

Purpose

Relay Type

Protected Zone

Clear Faults

 

Feeders

Transmission

Bus

Transformers

Generators

Motors

Intertie

Current

50, 51, 50/51B&M, 700C 851, 951, 1051

67, 67N, 700C, 851, 951, 1051

CDS240,CDS22 0, 700C, 851, 951, 1051

50, 51, CDS240, CDS220, 700C, 851, 951, 1051

51/27R, 51/27C, 700C, 851, 951, 1051, GPS, CDS240

51, 50/51, CDS240, CDS220, 700C, 851, 951, 1051

IPS100, 951, 1051

Differential

 

 

CDS240, CDS22087B

87T, CDS240, CDS220

87G, CDS240, CDS220

87G, CDS240, CDS220

 

Breaker Failure

700C, 851, 951, 1051

50BF, BPR, 951, 1051

951, 1051, CDS240

951, 1051, CDS240

700C, 851, 951, 1051, GPS, CDS240

700C, 851, 951, 1051, CDS240

IPS100, 951, 1051

Negative Sequence

700C, 851, 951, 1051

951, 1051

CDS240, CDS220, 700C, 851, 951, 1051

CDS240, CDS220, 700C, 851, 951, 1051

46N, CDS240, CDS220, 700C, 851, 951, 1051, GPS

46N, 47N, CDS240, CDS220, 700C, 851, 951, 1051

IPS100, 951, 1051

Purpose

Relay Type

Protected Zones

 

 

Feeders

Transmission

Bus

Transformers

Generators

Motors

Intertie

Relieve Stress

Excitation

 

 

 

951, 1051, CDS240

40Q, 60, GPS, CDS240

40Q, CDS240

IPS100, 951, 1051

Voltage

27/59*, 700V, 951, 1051

700V, 951, 1051

59NC, 700V, 951, 1051, CDS240

700V, 951, 1051, CDS240

27, 59, 59N, 700V, 951, 1051, GPS, CDS240

27, 27/59, 700V, 951, 1051, CDS240

IPS100, 700V, 951, 1051

Purpose

Relay Type

Protected Zones

 

 

Feeders

Transmission

Bus

Transformers

Generators

Motors

Intertie

Restore Power

Sync

25*, 951, 1051

25, 951, 1051

 

 

25, 25A, 951, 1051, GPS

 

 

Multiple Shot Reclose

79A, 79M, 700C, 700V, 851, 951, 1051

79A, 79M, 700V, 951, 1051

 

 

700V

 

IPS100, 951, 1051

Purpose

Relay Type

Protected Zone

 

 

Feeders

Transmission

Bus

Transformers

Generators

Motors

Intertie

Preserve System

Power

32R*, 951, 1051

951, 1051

951, 1051

951, 1051

32R, 32O/U, 951, 1051GPS

32R, 32O/U, 951, 1051

IPS100, 951, 1051

Frequency

81O/U*, 700V, 951, 1051

700V, 951, 1051

700V, 951, 1051, CDS240

700V, 951, 1051, CDS240

81O/U, 700V, 951, 1051, GPS, CDS240

700V, 951, 1051, CDS240

IPS100, 700V, 951, 1051


*=The use of this relay is suggested with distributed sources of generation.

For more information:

Industrial Solutions Section


Top | Welcome | Basler Electric - The Company | Exciters | Gen Controls | Regulators | Relays | Transformers |
News | Employment | Support | Site Map | Site Help | Basler Phone, Fax and Address | Privacy Policy
 

© Copyright Basler Electric Company - All Rights Reserved