Products

Retrofit Expert Chart

Basler Electric - Relay Retrofits The Upgrade Experts

 
Existing Relay Plug-and-Play Relays Solid State Retrofit Relays Retrofit Multifunction Numerical Relays
 

NO WIRING CHANGES*
Relays fit into existing cases.

NO PANEL DRILLING OR CUTTING IS REQUIRED.
Relays fit in existing panel cutouts.
(Wiring changes are required. Adapter plate may be needed)

SEL   
300G     BE1-11g (H-Case) w/adapter

547

    BE1-11i (H-Case) w/adapter
551,551C     BE1-700C, BE1-11f  (H-Case) w/adapter

351,351A,351S

    BE1-11f (H-Case) w/adapter

General Electric Models

269, 369, 469

    BE1-11m w/adapter

750/760, 735/737

    BE1-11f (J-Case) w/adapter
345, 745     BE1-11t (J-Case) w/adapter
489     BE1-11g (J-Case) w/adapter
G650     BE1-11i (J-Case) w/adapter
IAC, DIAC (basic)1,6 BE1-50/51B-214, 225 BE1-50/51B-218, 228 BE1-11fBE1-851
IAC (on shared terminals)6 BE1-50/51B-231 BE1-50/51B-232 BE1-11fBE1-851
IAC (arc flash)4,6 BE1-50/51B-237, 238, 2528, 2569 BE1-50/51B-239, 2538, 2579 BE1-11f,  BE1-851
IAC♦♦A (arc flash)3   BE1-50/51B-239  
IAC 66C (motor)1 BE1-50/51B-2157   BE1-851
IAC 66K (motor)1 BE1-50/51B-230, 234 BE1-50/51B-239 BE1-851
SFC¹ BE1-50/51B-229    

ACR11A-ACR11D

BE1-79A

 

BE1-11f, BE1-851

NLR21U   BE1-79A-109  
BDD
CFD
STD
  BE1-87T BE1-11t, BE1-CDS240
CFD
IJD
  BE1-87G BE1-11t, BE1-CDS240
CHC   BE1-50 BE1-851
CFF   BE1-81O/U BE1-11i, BE1-700V
GGP   BE1-32R BE1-11g
IAV   BE1-59N, BE1-59NC BE1-11f
IJS   BE1-25 BE1-11f
NLR     BE1-851
PJG   BE1-64F  
PVD21B1, PVD21D1 BE1-87B-111    
PVD
SBD
  BE1-87B  
SBC     BE1-11f
SFF   BE1-81O/U BE1-11i
SHR     BE1-700V (vertical w/ adapter)

SLR

  BE1-79M BE1-851

ABB (Westinghouse) Models

CO (basic/FT-11 case) BE1-50/51B-219, 226, 25810   BE1-851
CO (on shared terminals) BE1-50/51B-233    
CO (arc flash/FT-11 case) BE1-50/51B-235, 236, 2548, 2559   BE1-851
CO (arc flash/FT-11 cutout)   BE1-50/51B-244 BE1-851

CO (FT-21 case)5

BE1-50/51B-240

   
CO (FT-21 arc flash)5 BE1-50/51B 241    
RC2 BE1-79A    
CV-8   BE1-59, BE1-59NC BE1-700V

CW

   

BE1-11g

HU

 

BE1-87T

BE1-11t, BE1-CDS240

MMCO

   

BE1-851

SA-1

 

BE1-87G

BE1-11g

CA

 

 

BE1-11t, BE1-CDS240

CircuitShield O/C

 

BE1-50/51M

 

CircuitShield Type 64F

 

BE1-64F

 

DPU2000

   

BE1-11f  (w/adapter)

DPU2000R

   

BE1-11f

TPU

   

BE1-11t, BE1-CDS240

XASV
XM

   

BE1-25A (w/adapter)

  1. Existing case must have appropriate terminals for a multiple element relay
  2. See installation section of manual for covered applications
  3. Requires case change
  4. Minor wiring changes only
  5. Any pre-1966 CO relay being replaced should be referred to an application engineer for compatibility verification
  6. Replaces relays with CTs located at terminals 5 & 6, and trip outputs located at terminals 1, 2, & 3
  7. Output contacts are non-isolated. If isolated output contacts are required, contact an application engineer for compatibility verification.
  8. With Hot Line Tag (HLT) feature with one instantaneous element and one time element for 125V nominal tripping circuits.
  9. With Hot Line Tag (HLT) feature with two instantaneous elements and one time element on shared terminals for 125V nominal tripping circuits.
  10. Selectable 0.0 or 0.05 second, fixed, instantaneous delay.