BE1-59N Ground Fault Overvoltage Relay

Provides sensitive ground fault protection for ungrounded or high resistance grounded systems, generators, or capacitors.
 

  • BE1-59NOvervoltage element tuned to reject harmonics
  • Pickup down to 0.1 volts
  • Withstands full rated voltage continuously
  • Third harmonic undervoltage element for 100% stator protection
    (optional)
  • Instantaneous, definite, or inverse time characteristics
  • Drawout construction
     

Download Bulletin UBG for more information or download the instruction manual.

BE1-59NC Capacitor Neutral Overvoltage Relay

Provides sensitive protection for capacitor banks.

  • Helps avoid cascading capacitor failures
  • Sensing circuit rejects harmonics and noise to achieve higher sensitivity to 50/60 Hz neutral voltage
  • Includes an early warning alarm output on minor unbalances such as a blown fuse
  • Can be set to trip when voltage across any capacitor exceeds 110% of nominal
  • Drawout construction

Download Bulletin UHF for more information or download the instruction manual.

BE1-60 Voltage Balance Relay

Detects voltage imbalances on relay/control circuits.

  • Wide range adjustments (5% to 50%)
  • Six input sensing types to match various system configurations
  • Maximum trip time of 100 milliseconds
  • Drawout construction

Download Bulletin UBS for more information or download the instruction manual.
 

BE1-64F Ground Fault Relay


A solid-state device designed to detect abnormal grounding of ungrounded circuits, such as the field winding of a generator or motor.

  • Two fixed levels of ground detection – a pre-alarm level and a trip level.
  • Each level has an independent LED indicator and output contact.
  • Latching Target LED to indicate a trip condition even after the ground is removed.
  • The Target LED drive circuit is magnetically latched, so that the LED will return to the illuminated state following an interruption of control power to the BE1-64F.
     
Move your cursor over the picture to see the BE1-64F drawn out of its case.

Download Bulletin UHU for more information or download the instruction manual.
 

BE1-67N Ground Directional Overcurrent Relay

Microprocessor directional overcurrent relay for ground faults.

  • Twelve field selectable time-current curves
  • Directional and/or non-directional instantaneous (optional)
  • Directional element polarized by zero sequence current, zero sequence voltage, or phasor sum of zero sequence quantities

Download Bulletin UDR for more information or download the instruction manual.

Download a time current characteristic spreadsheet on the BE1-67.

BE1-79A Retrofit Reclosing Relay
Patent Pending

BE1-79AInstalls in existing ACR and NLR cases without panel or wiring changes.

  • Single BE1-79A configuration replaces multiple ACR and NLR types
  • Easy setup with front panel communications interface
  • Drawout construction

For more information on the application options the BE1-79A can provide,
see Application Note PC-79A01.

Download Bulletin UHN for more information or download the instruction manual.
 

BE1-79M Multiple Shot Reclosing Relay

Provides automatic reclosing of tripped circuit breakers in power transmission and distribution systems

  • BE1-79MContact selectable reclosing sequences are programmable for up to 4 reclosure attempts.
  • Ability to resume reclosing sequence if control power is interrupted.
  • Individually adjustable time-delayed reclosing attempts. Separate high speed “Pilot” reclose input and output are available for transmission reclosing applications.
  • Drawout construction

Download Bulletin UDL for more information or download the instruction manual.

 

BE1-81 O/U Digital Frequency Relay

Protects the system during over and/or underfrequency conditions.
 

  • BE1-81O/UDirect frequency trip settings
  • Accuracy of +/- 0.003 Hz
  • Pickup adjustable in increments of 0.01 Hz
  • 40 to 70 Hz operating range
  • Up to 4 independent over or underfrequency set points
  • Inverse or definite time delay characteristics
  • Supplied in S1 (drawout construction) or M1 case depending on option

Download Bulletin UBR for more information or download the instruction manual.

BE1-87B Bus Differential Relay

Economical high speed protection in a conventional package for all high impedance differential applications.

  • BE1-87B Bus Differential RelayHigh Impedance Differential provides optimum speed and selectivity
  • Single phase or three phase configurations allow space and cost benefits
  • Fully drawout, testable-in-case design, compatible with existing panel mount configurations.
  • CT Circuit Diagnostic function and Steady State Unbalance alarm verify external wiring and prevent misoperation.
  • Intentional 20msec delay timer can be inserted in the trip logic to aid in coordination when bus is tapped with high speed fuses
  • Supplied in S1 (drawout construction) or M1 case depending on option

Download Bulletin UHC for more information or download the instruction manual.

BE1-87G Variable Percentage Differential Relay

Protects rotating machines and reactors against internal faults.

  • Single-phase and three-phase units available
  • Sensitivity is adjustable from 0.1 to 1.6 amps
  • Variable percentage restraint characteristics
  • Drawout construction

Download Bulletin UBK for more information or download the instruction manual.

BE1-87T Transformer Differential Relay

Primary protection against internal faults in power transformers.
 

  • BE1-87TSingle phase sensing with up to five, single phase inputs
  • Three phase sensing with up to three sets of inputs
  • Provides precision ratio matching with 0.1 amp steps
  • Second and fifth harmonic restraint for overexcitation and inrush security
  • Phase shift compensation eliminates need for delta or auxiliary CTS

Download Bulletin UHA for more information or download the updated instruction manual.

Download a settings spreadsheet on the BE1-87T or the Transformer Differential Calculations Spreadsheet and Predicting Current Differential Relay Tripping and Targeting when Testing at Final Settings Tech Paper.

margin
Protective Relays
Application Table
Application Engineers
Regional Sales Managers
Sales Reps
Next Page
spacer
Industrial Solutions Section
ISO Certificate Link


Top | Welcome | Basler Electric - The Company | Exciters | Gen Controls | Regulators | Relays | Transformers |
News | Employment | Support | Site Map | Site Help | Basler Phone, Fax and Address | Privacy Policy
 

© Copyright Basler Electric Company - All Rights Reserved