Resource
Application Note: PC-FEEDER
This application note provides a step-by-step guide for implementing a Feeder Protection with Interlock scheme using BESTCOMSPlus®, BESTspace™, and preprogrammed logic files with the BE1-11 relay. It explains configuration, setup procedures, and interlocking logic that support feeder protection, reclosing, and backup overcurrent protection applications.
Resource
Application Note: PC-CONTROL
This application note provides a step-by-step guide for implementing an Overcurrent Protection with Control scheme using BESTCOMSPlus®, BESTspace™, and preprogrammed logic files with the BE1-11 relay. It explains configuration, setup procedures, and integrated control functions, including breaker failure, reclosing initiation, and manual breaker operation.
Resource
Application Note: PC-BASICLOGIC
This application note provides a step-by-step guide for implementing a Basic Overcurrent Protection scheme using BESTCOMSPlus®, BESTspace™, and preprogrammed logic files with the BE1-11 relay. It explains configuration, setup procedures, and protection logic for phase, neutral, and negative-sequence overcurrent applications.
Resource
Application Note: PC-BACKUPBUS
This application note provides a step-by-step guide for implementing a Backup Bus Overcurrent Protection scheme using BESTCOMSPlus®, BESTspace™, and preprogrammed logic files with the BE1-11 relay. It explains configuration, logic operation, and setup procedures that simplify deployment of backup bus protection applications.
Resource
Logic Scheme: Overcurrent with Reclosing Logic (BE1-11)
This compressed file includes an application note, BESTspace™ file, printable screenshots, and logic file that demonstrate overcurrent protection with automatic reclosing using the BE1-11, providing configuration examples and implementation guidance for fault detection, breaker control, and service restoration applications.
Resource
Logic Scheme: Overcurrent with Control Logic (BE1-11)
This compressed file includes an application note, BESTspace™ file, printable screenshots, and logic file that demonstrate overcurrent protection with integrated control logic using the BE1-11, providing configuration examples and implementation guidance for fault detection, protective functions, automation, and system control applications.
Resource
Technical Paper: Negative-Sequence Relaying Applications in Ungrounded and High-Impedance Grounded Industrial Systems
This technical paper examines the application of negative-sequence protection in ungrounded and high-impedance grounded industrial power systems, demonstrating how negative-sequence sensing can improve phase-to-phase fault detection and protection performance.
Resource
Technical Paper: Using GOOSE Messages in a Main-Tie-Main Scheme
This technical paper explains how IEC 61850 GOOSE messaging can be applied in main-tie-main schemes to improve system reliability, simplify communications wiring, and support high-speed transfer and switching operations in power systems.